Professional Lambda Meter
The MoTeC Professional Lambda Meter (PLM) accurately determines exhaust gas mixture strength over a wide range of engine operating conditions with a fast response time. This device has been designed to be quick and easy to use, whilst allowing a calibration engineer all of the power and configurability required for OE emissions development and certification work.
Weighing only 135 gms and with a robust aluminium enclosure it can be conveniently mounted singularly, or in multiples, in almost any application. The operating range of the device is between 0.7 and 32.0 Lambda. For Gasoline/Petrol this equates to an Air/Fuel Ratio range of 10.3:1 to 470:1.
The display may be set to show Lambda, Air Fuel Ratio or Equivalence Ratio for any sensor compatible fuel (Gasoline/Petrol, Alcohol, Gas, Diesel or "blend" fuel as defined by the user). The resolution of the display (decimal points), display update rate, display filtering, backlight intensity may all be defined by the user with the Windows setup software provided.
The MoTeC Professional Lambda Meter provides an differential Analog Voltage Output that may be connected to an Analog Meter or other measurement instrument such as a Data Logger or Chart Recorder. The output may be defined by the user to be linear or non-linear in relation to the measured units. The PLM also supports 1 Mbit CAN and/or RS232 data links to devices such as the MoTeC ADL2 or SDL for transmission of sensor and diagnostic data. Comprehensive diagnostic and status channels are also provided.